Furnace Structure | Single heating zone 、High purity Al2O3 insulation chamber guarantees excellent temperature uniformity. 、Cooling fans are installed at the bottom of the furnace to ensure efficient ventilation. 、Sliding flange assembly is made of stainless steel. 、Dual quartz tube:100mm Dia. exterior tube and suspended by 80 mm Dia. interior tube. Metallic foil(Graphene Growth Substrate) will be wrapped around inside tube surface for CVD reaction 、Heating zone length: 440mm Constant temperature heating zone length: 120 (±1°C) 400~1100°C | Dual heating zone 、High purity Al2O3 insulation chamber ensures excellent temperature uniformity. 、Cooling fans are installed at the bottom of the furnace to ensure efficient ventilation. 、Max. Temperature: 1200℃and continuous temperature: 1100°C. 、Two Heating Zones controlled separately: Dual direction sliding rails to ensure furnace moves smoothly. 、200mm length for each heating zone, 400mm total heating length 、250mm constant temperature zone if the two zones heating at same temperature 、500oC max temperature difference if place a thermal block in between two zone | |||||||||||||
Power | Single heating zonePower: 208-240VAC, 50/60Hz, single phase, 2.5KW ( 20A Breaker required) | Dual heating zonePower: 208-240VAC, 50/60Hz, single phase, 4 KW ( 50A Breaker required) 10 feet power cable with no plug(ask a licensed electrician to do the plug) | |||||||||||||
Heating Temperature | 、Max. Temperature: 1100°C 、Continuous Temperature: 1000°C | ||||||||||||||
Heating amp; Cooling Rate | Max. heating and cooling rates depend on working temperature. Please click on tables below to see the Max. heating amp; cooling rate varies at different temperature range.( You shall calibrate temperature and heating cooling rate at your working condition before use ) Heating plot Cooling plot | ||||||||||||||
Fused Quartz Tubes | 、High purity quartz tube: Two pairs of vacuum sealed flanges with water cooling jackets and stainless steel needle valves 、Outside tubeEQ-QZTube-101D-1400: OD:4"x ID: 3.8" X 55" Length (OD 100xID 96x1400 mm ) 、Inside tubeEQ-QZTube-80D-1800: OD:3.15:xIDx2.95"x70.8" Length (OD 80xID 75x1800 mm | ||||||||||||||
Vacuum Flanges | Using dual tube for inducing CVD growth onmetal foil(wrapped around interior tube surface):Please click for a related article: "Roll-to-roll production of 30-inch graphene films for transparent electrodes " 、1-1. Shown below, one pair of SS304 flanges to seal both the outside tube and the space between the outside tube and inside the tube (this space is considered as a reaction chamber). º Left side flange: Barb fitting with needle valve as gas inlet,a digital vacuum gauge with measuring range 10^-4 to 1000 torr, water cooling inlet/outlet included º Right side flange: Right angle valve with KF25 flange fitting, a vacuum release needle valve, water cooling inlet/outlet included 、1-2. Leave both ends of inside tube open for gas cooling.
| ||||||||||||||
Temperature Controller | 、PID automatic control with 30 programmable segments for precise control of heating rate, cooling rate and dwell time. 、Built-in over temperature alarm and protection allows for operation without any attendant. 、Over temperature protection and alarm allows for operation without attendant(s). 、+/- 1 ºC temperature accuracy. 、RS485 Communications Port. º Advanced Temperature Control (Optional) º Temperature control software kit (for YD518P series controllers) + 15" laptop package is available at the options bar. Click for the detail information about the software kit. º You may upgrade the temperature controller to the Eurotherm 3504 Temperature Controllerwhich is fully compatible with LabVIEW. This package includes a Eurotherm 3504 programmer, a communication cable (RS485 - USB) and a software CD. Click the pic below to view the full spec of Eurotherm 3504 temperature controller. | ||||||||||||||
Mass Flow Meters amp; Gas Mixing Station | 、4 precision mass flow controller ( MFC) with digital display and adjusting knob are installed on the left bottom case to control gas flow rate: 、4 Gas channels (contact STR-sales if need more) º MFC 1: Control range from 0~100 SCCM º MFC 2: Control range from 0~200 SCCM º MFC 3: Control range from 0~200 SCCM º MFC 4: Control range from 0~500 SCCM 、Flowing rate accuracy:±1% FS 、Gas inlet and outlet: 1/4" Swagelok tube connector 、One 80mL gas mixing tank is installed in bottom case 、Each gas channel has a stainless steel needle valve for easy on/off 、The flow rate is adjustable from the MFC panel | ||||||||||||||
Vacuum Pump Station and valves | Optional 1: 、Pfeiffer's High Speed (226L/min) Oilless DryVacuum Pump, 10E-3 Torr Limitis installedinside a heavy duty mobile cart. Please click the picture below for more details. 、KFD25 adapterand stainless steel pipeareconnected between pump and tube flangewith a precision ball valve. 、10E-2 Torr vacuum can be achieved insideprocessing tube 、Digital vacuum gauge(made in the USA) is installed on the left side flange. 、(Optional) For higher vacuum level to 10^-5torr, please order below mobile turbo pump. | Optional 2: 、The heavy duty Double Step Rotary Vane Vacuum Pump with Exhaust Filter amp; KF-D25 Inletis installed inside a heavy duty mobile cart. Please click the picture below for more details. 、6.7x10-4mbar vacuum can be achieved inside processing tube 、Digital vacuum gauge(made in the USA) is installed on the left side flange. Please click the second picture below for more details 、For higher vacuum level to 10^-5 torr, please order below mobile turbopumpat extra cost: | |||||||||||||
Water Cooling Function | Water cooling on the flange is mainly for cooling down the o-ring inside the flange to ensure the best-sealed chamber at high temperature: 、Water cooling flanges require gt;= 10L/M water flow. 、You may use tap water as the coolant, but we strongly suggest you to use a recirculating water chiller for environmental considerations. Please click thumb below to order the water chiller at extra cost.
| ||||||||||||||
Optional Parts (building up a single tube furnace) | You can build up an 80mm Dia. single tube reaction chamber by ordering extra sealing flanges and install them onto interior tube: 、Left side flange: Barb fitting with needle valve as gas inlet and 1/4'' feedthrough fitting for customer to insert a measuring sensor (e.x. an insertable thermocouple for temperature calibration) 、Right side flange: KF25 fitting with mechanical gauge and vacuum release valve (click to enlarge the picture) click here to choose a crucible | ||||||||||||||
Dimension | 、Furnace: 550x380x520mm 、Bottom mobile casex2: 600x600x600mm (one for gas mixing station and the other for vacuum pump) | ||||||||||||||
Shipping | 、Shipping Weight: ~800 lb 、Shipping by freight with three pallets 、Crating fee will be applied | ||||||||||||||
Warranty | One year limited manufacturer's warranty (Consumable parts such as processing tubes, O-rings, and heating elements are not covered by the warranty, please order replacements at related products below). | ||||||||||||||
Laptop, software amp; WiFi Control (Optional) | 、Brand new laptop with Microsoft Window 10 and Microsoft Office 2013 (30 days free trial) for immediate use. 、 Temperature Control System (EQ-MTS01)enables user to edit temperature profile, manage heat-treatment recipe, record and plot data for STR-furnaces. 、A wireless remote control provides up to 300 meters operating range. 、Above features are available upon request at an extra cost (up to $1,000). Please contact us for more information. 、Note: The software is only compatible with Yudian Temperature Controller | ||||||||||||||
Compliance | 、CE Certified 、All electric components ( gt;24V) are UL / MET / CSA certified 、The furnace is ready to pass TUV(UL61010) or CSA certification at extra cost. ( please click marks below to learn details ) | ||||||||||||||
Application NotesClick here to learnthe installation of a gas regulator | 、Tube furnaces with quartz tubes are designed for using under vacuum and low pressure < 0.2 bars / 3 psi / 0.02 Mpa 、Attention: A two-stage pressure regulator must be installed on the gas cylinder to limit the pressure to below 3 PSI for safe operation.Click here to learnthe installation of a gas regulator. 、The flow rate for gasses should be limited to < 200 SCCM (or 200 ml/min) for reducing thermal shocks to the tube 、Vacuum limit definition for all quartz tube furnaces: * Vacuum pressures may only be safely used up to 1000°C 、Click here to learnHow to set up quartz/ ceramic tube and vacuum flange for STR-Tube furnace. 、One slide stopping clamp is included for holding the position of the furnace. 、After CVD, the graphene must be transferred from the metal catalyst to another substrate for most applications. By using the graphene transfer tape, the residue can be low. | ||||||||||||||
Warning | Fast sample cooling can be achieved by sliding the heating chamber away. Please wear protective gears such as heat resistant suit amp; gloves if you intend to do so. DO NOT TOUCH THE TUBE SURFACE WHEN IT IS HOT! | ||||||||||||||
Operation Instructions | (Operation and Installation Video) (Furnace-Sliding Test Demo) |